#30 of 30 · AI lab

xAI (Grok)

81 gas turbines across two sites, most of them beyond their permits.

Palo Alto, California·x.ai ·Verified Oct 16, 2026
CMostly estimates
Index score
Mostly estimates

In plain words

How scores work

xAI scores 19 out of 100 — laggard. Little or no disclosure, fossil-backed capacity, or active disputes with regulators and communities. Confidence in this score is mostly estimates (C).

What helps

  • Nothing on record.

What hurts

  • Efficiency · Closed frontier models with no disclosures of any kind.
  • Carbon · Colossus has used methane gas turbines for primary power since opening; 35 turbines were on site in 2025 versus 15 permitted.
  • Carbon · Colossus 2 added 19 turbines in spring 2026 for a total of 46 gas units — above the 41 permitted — supplying more than 500 MW.

What nobody knows

  • Per-prompt energy disclosed
  • Per-prompt water disclosed
  • Training emissions in model cards
  • Annual environmental report
  • Location-based Scope 2 reported
  • +4 more

xAI's Colossus supercomputer in Memphis has run on methane gas turbines since it opened. Aerial imagery counted 35 turbines on site against a permit for 15; the Southern Environmental Law Center estimates more than 2,000 tons of NOx a year. At Colossus 2 in Southaven, Mississippi, records show 46 gas units by May 2026 against a permit for 41, and the $80 million water-recycling plant xAI promised Memphis was paused in April 2026. The company has disclosed no energy, water or emissions data.

Products
Grok · Colossus
Hosting
Own Colossus campus in Memphis, Tennessee and Colossus 2 in Southaven, Mississippi, on TVA power plus on-site gas generation.

Key figures

Per-prompt and fleet metrics. Hover a title for what it means; open “How we got this number” for the working.

How to read the labels:Company figureCompany figure. Published by the company itself. We take it as given and record the scope next to it.Measured independentlyMeasured independently. Measured or estimated by researchers or analysts with no stake in the result.ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.DerivedDerived. Arithmetic on a disclosed or independent input using a published conversion factor.Not disclosedNot disclosed. The company publishes nothing on this and no defensible estimate exists.— hover any label.
Energy per promptElectricity used to answer one typical request. Under 0.3 Wh is good. A 10 W LED bulb uses 0.3 Wh in about two minutes.
0.30
Wh / typical prompt
≈ 25.0 smartphone charges per 1,000 prompts
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.Epoch AI

ecogpt.co estimate; no company figure.

How we got this number

Grok's frontier models are closed and unmeasured; comparable in class to GPT-4o, which Epoch puts at about 0.3 Wh per typical query. Uncertainty roughly ±3×.

Water per promptWater evaporated cooling the servers for one request. Scope matters: on-site cooling only, or also the water used to generate the electricity (which adds ≈1.8 mL per Wh).
0.18
mL / typical prompt
≈ 0.36 500 mL bottles per 1,000 prompts
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.Epoch AIFOX13 Memphis

On-site cooling only, so comparable with Google and OpenAI's figures.

How we got this number

0.3 Wh per prompt × 0.6 L/kWh (estimated WUE from Colossus 1's reported water draw). Counting the water evaporated to generate the electricity adds ≈0.54 mL.

Carbon per promptGreenhouse gas from one request on the grid where it actually runs. Below 0.1 g is clean. A kilometre in a petrol car is about 170 g.
0.150
gCO₂e / typical prompt
≈ 0.88 km driven (petrol car) per 1,000 prompts
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.Epoch AI

Location-based: what the grid actually emitted. Renewable certificates would bring the market-based figure near zero.

How we got this number

0.3 Wh × 500 gCO₂/kWh (on-site gas turbines, location-based). Most of Colossus runs on simple-cycle gas turbines at roughly 500 gCO₂/kWh.

Annual emissionsThe company's whole yearly footprint, in million tonnes of CO₂e. Clouds and device makers dwarf pure labs because they also count shops, logistics or products. Compare the trend, not the size.
2.80
MtCO₂e / year (AI compute only)
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.SemiAnalysisData Center Dynamics

Location-based estimate for the AI fleet only; not comparable with a full corporate inventory.

How we got this number

800 MW × 8,760 h × 80% utilisation × 500 gCO₂/kWh (on-site gas turbines). Compute only — nothing else the company does is counted.

Emissions trendDirection of travel against last year or the company's own baseline. Negative is good. Positive means the AI build-out is outrunning clean energy.
+150
% (Colossus 2 build-out)
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.Data Center Dynamics
How we got this number

Colossus 2's turbines alone exceed Colossus 1's entire draw; compute and on-site combustion more than double between 2025 and 2026.

Water per kWh (WUE)Litres of water consumed per kilowatt-hour of server electricity, across the fleet. 0.15 is excellent, 0.3 is good, 1.8 is the US data-centre average.
0.60
L/kWh
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.FOX13 MemphisSemiAnalysis
How we got this number

Colossus 1 uses more than one million gallons a day (3,800 m³) against roughly 7,200 MWh of daily electricity, i.e. ≥0.5 L/kWh of evaporative cooling.

Clean electricityShare of electricity matched with renewable or carbon-free sources. Annual matching counts certificates bought anywhere; hourly matching on the same grid is far stricter.
30.0
% (TVA grid share minus on-site gas)
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.Inside Climate NewsData Center Dynamics
How we got this number

TVA's grid is roughly 60% nuclear and hydro, but more than half of Colossus's load is met by on-site gas turbines; the blend is about 30% carbon-free.

Hardware & materials

The chips, power, copper and future e-waste behind the fleet — the part sustainability reports leave out

Factors we use
AI chips in service
340,000
accelerators across Colossus 1 and 2
≈ 4,722 racks of 72 GPUs
Measured independentlyMeasured independently. Measured or estimated by researchers or analysts with no stake in the result.SemiAnalysisData Center Dynamics

GPUs, TPUs or custom accelerators the company runs. Analyst figures are in H100-equivalents, company figures in physical chips.

How we got this number

≈200,000 H100/H200 plus 30,000 GB200 at Colossus 1 (SemiAnalysis); at least 110,000 GB200 at Colossus 2, heading for 550,000.

Power draw
800
MW (2026)
≈ 600,000 US homes' worth of power
ecogpt.co estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.SemiAnalysisData Center Dynamics

Megawatts the AI fleet pulls. One megawatt runs roughly 750 US homes.

How we got this number

Colossus 1 draws about 300 MW (SemiAnalysis); the 46 gas units installed at Colossus 2 by May 2026 add more than 500 MW of on-site generation, with 2 GW the stated goal.

Electricity a year
5.61
TWh / year
≈ 534,286 US homes for a year
DerivedDerived. Arithmetic on a disclosed or independent input using a published conversion factor.SemiAnalysisData Center Dynamics

Terawatt-hours per year. One TWh is a year of electricity for about 95,000 US homes.

How we got this number

800 MW × 8,760 h × 80% utilisation. Compute fleet only.

Carbon baked into the hardware
175
ktCO₂e embodied in chips and servers
≈ 38,000 petrol cars driven for a year
DerivedDerived. Arithmetic on a disclosed or independent input using a published conversion factor.SemiAnalysisData Center DynamicsarXiv 2607.05408NVIDIA developer blog

CO₂e emitted making the chips and servers before they answer a single prompt.

How we got this number

340,000 accelerators × 514 kg CO₂e each (chip plus share of the host server). Emitted in manufacturing, before the first prompt is served.

Future e-waste
5,780
tonnes of servers to retire within ~5 years
≈ 32 empty Boeing 747s by weight
DerivedDerived. Arithmetic on a disclosed or independent input using a published conversion factor.SemiAnalysisData Center DynamicsNVIDIAThe Register

Tonnes of server hardware that will be retired in three to five years.

How we got this number

340,000 accelerators × 17 kg of server hardware each. Tomorrow's e-waste unless reused; generative AI could produce 2.5 Mt of it a year by 2030.

Copper in the build
21,600
tonnes of copper in the build
≈ copper for 260,241 electric cars
DerivedDerived. Arithmetic on a disclosed or independent input using a published conversion factor.SemiAnalysisData Center DynamicsBHPS&P Global Market Intelligence

Tonnes of copper in cabling, busbars and transformers.

How we got this number

800 MW × 27 t of copper per MW (cabling, busbars, transformers).

Fossil generators on site
81.0
gas turbines observed or installed (35 at Colossus 1, 46 at Colossus 2)
≈ 211 MW of backup capacity
Company figureCompany figure. Published by the company itself. We take it as given and record the scope next to it.Inside Climate NewsData Center Dynamics

Diesel backup units or gas turbines at the data centres, permitted or observed.

How we got this number

Permits covered 15 and 41 respectively.

Hardware reused or recycled
—
No hardware reuse or e-waste figure published.
Not disclosedNot disclosed. The company publishes nothing on this and no defensible estimate exists.

Share of retired servers and parts given a second life.

Mineral depletion
—
Only Mistral has published a mineral-depletion figure.
Not disclosedNot disclosed. The company publishes nothing on this and no defensible estimate exists.

Kilograms of antimony-equivalent, the life-cycle unit for scarce minerals consumed.

Score breakdown

Each pillar is 0–100; weights are fixed across the index

Energy efficiency — How much electricity one answer costs.weight 20% · confidence D
40
Carbon intensity — How clean that electricity is, and whether total emissions are rising.weight 25% · confidence B
12
  • Colossus has used methane gas turbines for primary power since opening; 35 turbines were on site in 2025 versus 15 permitted. Inside Climate NewsData Center Dynamics
  • Colossus 2 added 19 turbines in spring 2026 for a total of 46 gas units — above the 41 permitted — supplying more than 500 MW. Data Center Dynamics
Water — How much water the data centres consume, and whether it is replaced.weight 15% · confidence C
30
  • Colossus 1 needs more than a million gallons of water a day; xAI broke ground on an $80M greywater plant to spare the Memphis Sand aquifer, then paused it indefinitely in April 2026. Restart is now promised for 2027. Data Center DynamicsFOX13 Memphis
Transparency — How much the company actually publishes.weight 20% · confidence D
5
Commitments — Whether it has dated, measurable climate and water targets.weight 10% · confidence C
15
Conduct — How it behaves: permits, lawsuits, gas turbines, community water.weight 10% · confidence B
8
  • SELC, Earthjustice and the NAACP sent a notice of intent to sue under the Clean Air Act; NAACP and Young, Gifted and Green appealed the 15-turbine permit. Data Center DynamicsTennessee Lookout
  • Turbine installations at Colossus 2 exceeded the permitted count within two months of approval. Data Center Dynamics
  • xAI calls the allegations 'baseless and politically driven'. Data Center Dynamics

Models

What this company ships, and what each prompt costs

ModelWeightsEnergy / promptWaterTraining CO₂e
Grok 3 / 4
Frontier (undisclosed)
Closed0.30 Wh Estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.0.180 mL Estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.150,000 t Estimateecogpt.co estimate. Our own estimate from published factors. The working is shown next to the number; treat it as an order of magnitude, not a measurement.

Where the compute lives

Named sites from company disclosures and press reporting

OperationalConstructionPlanned
  • ColossusMemphis, Tennessee, USA · 35 gas turbines counted vs 15 permitted; ≈300 MW.
  • Colossus 2Southaven, Mississippi, USA · 46 gas units vs 41 permitted; >500 MW.